All PDF forms require the free Adobe
Acrobat Reader.
|

Printable
PDF
Contact Caen regarding this unit!
Support
and Warranty
|
|
Highlights
End-to-end I/O performance in RAID5 configuration:
- Sequential Reads: 566 MB/s
-Sequential Writes: 484 MB/s
Two (2) Fibre host channels; transfer rate up to 400MBps per channel
Accommodates sixteen (16) the latest 3Gbps, SATA-II disk drives; backward compatible with SATA-I drives
Highest fault tolerance with RAID6 configuration
Support up to 2GB DDR RAM DIMM modules
Highest density in a 3U chassis supporting up to 12TB storage
capacity
Optional hot-swappable battery backup units (BBUs)
Dual-speed fans to reduce system noise and power consumption
Effortless management through the LCD keypad, RS-232C terminal, or Java-based RAIDWatch Manager over the Internet
Overview
The Comet SATA-II 16eF4 subsystem combines the high performance,
reliability, and scalability of 4G Fibre host interfaces with
the low cost and high capacity benefits of 3Gbit per second
(3Gbps) Serial ATA (SATA) drive technology. The 4Gbps Fibre
Channel doubles the storage network's performance speed while
maintaining backward-compatibility with 2Gb systems. Employing
Caen's renowned, custom ASIC 400 RAID engine, the subsystem
is designed to satisfy the speed, capacity, and reliability
demands of medium- to large-sized enterprises.
The SATA-II 16eF4 comes in an enhanced, cableless, backplane-based, high-density 3U chassis. The single RAID controller provides two 4Gbps Fibre host channels and sixteen 3Gb SATA-II drive channels that are routed through the backplane board to the sixteen drive trays installed in the front panel of the subsystem. By moving to the 4Gb interface connection and the second generation of 3Gb SATA-II technology, the SATA-II 16eF4 offers massive storage capacity and accelerates the storage data path. Its high performance and full bandwidth assure the highest level of data availability in a safe environment.
|
Reliability
The SATA-II 16eF4 fully supports advanced, enterprise-class RAID
features. Any logical drives, logical volumes, and logical partitions
existing within the SATA-II 16eF4 can be configured using any RAID
level including RAID6, a proprietary extension of RAID5 that improves
fault tolerance with the ability to handle the failure of any two
drives in the array.
The subsystem further guarantees data safety by supporting an optional
battery backup unit (BBU) and the installation of an uninterruptible
power supply (UPS). The BBU provides power to cache memory during
a power failure, while the UPS extends the operating time for the
entire subsystem if a power shortage occurs.
Combined with Caen's seamless firmware features such as DrvSmart
and SysSmart, the Comet SATA-II 16eF4 delivers reliable, consolidated
storage for today's enterprise environments.
Availability
The SATA-II 16eF4 provides quiet operation with unsurpassed reliability
for even the most extreme storage environments. To ensure a high
level of system availability, the unique cableless chassis design
allows all critical components such as disk drives, power supplies,
and cooling modules to be redundant and hot-swappable. These modules
are integrated into the passive backplane via board-to-board connectors
to increase availability and eliminate single points of failure,
thus making this subsystem an excellent choice for mission-critical
applications.
Serviceability
This reliable, SAN-ready subsystem features a cableless, backplane-based
design to eliminate problems associated with cable connections and
offer a higher level of serviceability and hot-swappability. The
subsystem's modular nature and the easy accessibility to all field
replaceable units (FRUs) through its front and rear panels ensure
easy subsystem maintenance.
Manageability
The subsystem's built-in Ethernet port ensures easy access to the
Java-based RAIDWatch Manager for remote configuration, management,
and monitoring functions. RAIDWatch Manager provides "Install Once,
Run Anywhere" convenience with a user-friendly graphical user interface.
Additionally, the subsystem can be accessed through the LCD keypad
panel, RS-232C terminal, and telnet.
The RAIDWatch Configuration Client sub-module gives system managers
the power of real-time monitoring even when they are away from the
subsystem by providing a variety of notification methods including
email, fax, LAN broadcast, SNMP traps, MSN Messenger, ICQ, SMS messages,
and the configuration utility screen.
Caen Smart Technologies
With over 10 years of RAID firmware development experience, Caen's
innovative Smart technologies have been applied extensively to our
RAID firmware functionalities to provide enhanced storage solutions
for every customer environment from small organizations to large
enterprises. The technologies enhance I/O processing, drive handling,
and system management.
IO Smart
IOSmart allows for the flexible configuration of logical drives,
logical volumes, and logical partitions and ensures instant RAID
availability via background logical drive initialization. The firmware's
embedded intelligent algorithms, such as the Adaptive Write Policy
and Guaranteed Latency I/O, improve sequential write performance
and ensure the fast and continuous flow of data.
DrvSmart
The Comet SATA-II 16eF4 also includes the DrvSmart technology that
provides an easy way to safely store data. One of the main DrvSmart
functions, Media Scan, retrieves data from degraded or damaged hard
drives and handles low quality drives in both the degraded mode
and during the rebuild process. Other DrvSmart features include
disk cloning, drive roaming, SMART, transparent resetting of non-responsive
hard drives, and RAID parity update tracking and recovery.
SysSmart
SysSmart combines enclosure monitoring and firmware management capabilities
in order to minimize the chance of downtime caused by hardware failures.
The
Auto Data Protection mechanisms ensure data safety. Other SysSmart
functions include event-triggered and various other monitoring utilities
and approaches combined with the powerful RAIDWatch Manager. Component
status, voltage and temperature readings, and system events are
instantly reported through the manager's graphical interface.
Specifications
Subsystem Characteristics
PowerPC RISC CPU,
1MB L2 Cache
ASIC400 RAID engine
Default DDR cache
memory: 512MB
FC-4G host channels:
2
BBU per controller
Option
LCD keypad panel:
1
COM ports: 2
10/100 Ethernet port:
1
Diagnostic LEDs on
all FRUs
Drive Interface
Number of disk trays:
16
SATA-II/SATA-I
Host Connection Ports
SFP ports to optical
fiber: 2
Data single channel
bandwidth 400MBps
Auto-negotiate (2
and 4Gbps)
F_port, FL_port
Tag command queuing
Multiple target IDs
RAID Configurations
RAID levels 0, 1(0+1),
3, 5, 6, 10, 30, 50, 60, JBOD
Max. 1024 LUNs
Multiple array configurations
Automatic background
rebuild
Smart Technologies
High Availability
Redundant, hot-swappable
FRUs
Subsystem self-diagnostics
Optional battery
backup unit
UPS status detection
Hot-spare disk drives
Cluster ready
Management Software
RAIDWatch GUI software
Terminal via RS-232C
Telnet over Ethernet
LCD keypad panel
Event notification methods:
Email, Fax
LAN broadcast
SNMP traps
Cell phone message
SMS
Instant messages
MSN/ICQ
OS Support
Microsoft Windows
NT
Microsoft Windows
2000 Server
Microsoft Windows
2003 Server
Sun Solaris ver.
9/10
Red Hat Linux ver.
8/9, 64 Bit, Enterprise ver. 3
SuSe: Linux ver.
8/9, 64 Bit
Fedora 64 Bit
MAC OSX Version 10.4
Requirements
AC Input:
100VAC at 10A; 240VAC at 5A with PFC (auto-switching)
DC Output:
12V-32A; 5V-32A; 3.3V-30A
Relative Humidity:
5% to 95% non-condensing
Operating Temperature:
0 C to 40 C
Dimensions
3U, 19-inch rackmount chassis
Chassis without handles:
445(W) x 130(H) x 488.2(D) mm
(17.5 x 5.1 x 19.2 inches)
Chassis with handles:
482.6(W) x 131(H) x 504.3(D) mm
(19 x 5.2 x 19.9 inches)
Download
the printable PDF from our FTP site!
Please contact our sales team at sales@caeneng.com or our service department at support@caeneng.com if you want to find out more!
Caen Engineering, terms of service, Find an error on the site? Contact the Webmaster at danielle@caeneng.com. © 2005, Caen Engineering |